b'& SPRAYERS APPLICATORS SPRAY TIPSHANDLING DRY MATERIAL"3-D" NOZZLE SPRAY TIPSProven to deliver up to a 10% increase in pre-emerge weed control compared to a conventional flat fan (Syngenta UK)Creates the optimum droplet size for coverage, fewer droplets bounce off or drift away60-75% drift reduction compared to flat fan nozzles, achieving 2 Star LERAP rating at & HOSE TRAILERS VALVES &STRAINERS specific nozzle size/pressure combinationsInclined spray is designed to be installed alternating forward and backward on boom to provide 3-dimensional coverage on vertical targets such as grass weeds, soil clods and broad leaved canopiesPWM compatible; Install 3D nozzles facing the same direction when using with PWM ACCESSORIES TANKS &systems at less than 30 HzFastCap version utilizes the SnapLock cap technology, reducing installation torque requirement by 73% (Internal testing - standard FastCap versus SnapLock cap)Part # DescriptionFC-3D100-* 3D Nozzle Spray TipsPUMPS NOZZLES, TIPS NH3 TECHNICAL INDEX 1. SnapLock cap version available for easyNozzle Droplet Pressure Flow Speed (MPH) - 20 inch nozzle spacing 1 installation and removalSize Size (PSI) (GPM) Gallons per Acre 2. Angled bore for superior coverage and5.0 7.5 10.0 12.5 15.0 17.5 20.0 22.5 25.0 27.5 30.0 drift reductionC 10* 0.08 4.5 3.0 2.2 1.8 1.5 1.3 1.1 1.0 0.9 0.8 0.7 2M 15* 0.09 5.5 3.6 2.7 2.2 1.8 1.6 1.4 1.2 1.1 1.0 0.9 3. Highly engineered exit orifice for dropletM 20 0.11 6.3 4.2 3.2 2.5 2.1 1.8 1.6 1.4 1.3 1.1 1.1 uniformity, reduced drift and uniformF 30 0.13 7.7 5.1 3.9 3.1 2.6 2.2 1.9 1.7 1.5 1.4 1.3 spray across the boomF 40 0.15 8.9 5.9 4.5 3.6 3.0 2.5 2.2 2.0 1.8 1.6 1.5 3015 F 50 0.17 10.0 6.6 5.0 4.0 3.3 2.8 2.5 2.2 2.0 1.8 1.7FITTINGS EQUIPMENT PLANTERF 60 0.18 10.9 7.3 5.5 4.4 3.6 3.1 2.7 2.4 2.2 2.0 1.8F 70 0.20 11.8 7.9 5.9 4.7 3.9 3.4 2.9 2.6 2.4 2.1 2.0 Features Part NumbersF 80 0.21 12.6 8.4 6.3 5.0 4.2 3.6 3.2 2.8 2.5 2.3 2.1F 90 0.23 13.4 8.9 6.7 5.3 4.5 3.8 3.3 3.0 2.7 2.4 2.2 Common Use Weed control,FastCapsM 10* 0.10 5.9 4.0 3.0 2.4 2.0 1.7 1.5 1.3 1.2 1.1 1.0 plant healthM 15* 0.12 7.3 4.8 3.6 2.9 2.4 2.1 1.8 1.6 1.5 1.3 1.2 FC-3D100-015Alternating Tapered M 20 0.14 8.4 5.6 4.2 3.4 2.8 2.4 2.1 1.9 1.7 1.5 1.4 Pattern Flat Fans FC-3D100-02M 30 0.17 10.3 6.9 5.1 4.1 3.4 2.9 2.6 2.3 2.1 1.9 1.7F 40 0.20 11.9 7.9 5.9 4.8 4.0 3.4 3.0 2.6 2.4 2.2 2.0 Advanced TaperedFC-3D100-02502 F 50 0.22 13.3 8.9 6.6 5.3 4.4 3.8 3.3 3.0 2.7 2.4 2.2 Technology Flat FanF 60 0.24 14.5 9.7 7.3 5.8 4.8 4.2 3.6 3.2 2.9 2.6 2.4 FC-3D100-03F 70 0.26 15.7 10.5 7.9 6.3 5.2 4.5 3.9 3.5 3.1 2.9 2.6 Material Polyacetal FC-3D100-035F 80 0.28 16.8 11.2 8.4 6.7 5.6 4.8 4.2 3.7 3.4 3.1 2.8F 90 0.30 17.8 11.9 8.9 7.1 5.9 5.1 4.5 4.0 3.6 3.2 3.0 Spray Angle 100 FC-3D100-04C 10* 0.13 7.4 5.0 3.7 3.0 2.5 2.1 1.9 1.7 1.5 1.4 1.2 10-90 PSI FC-3D100-05M 15* 0.15 9.1 6.1 4.5 3.6 3.0 2.6 2.3 2.0 1.8 1.7 1.5 Pressure Range (0.7-6 BAR)M 20 0.18 10.5 7.0 5.3 4.2 3.5 3.0 2.6 2.3 2.1 1.9 1.8 FC-3D100-06M 30 0.22 12.9 8.6 6.4 5.1 4.3 3.7 3.2 2.9 2.6 2.3 2.1 1. SnapLock cap version available for easyConfiguration Tips, SnapLockM 40 0.25 14.9 9.9 7.4 5.9 5.0 4.2 3.7 3.3 3.0 2.7 2.5 installation and removal025 F 50 0.28 16.6 11.1 8.3 6.6 5.5 4.7 4.2 3.7 3.3 3.0 2.8 1 FC-3D100-08F 60 0.31 18.2 12.1 9.1 7.3 6.1 5.2 4.5 4.0 3.6 3.3 3.0 Optimum Boom Height 2. Angled bore for superior coverage andReplacement Tip StrainerF 70 0.33 19.6 13.1 9.8 7.9 6.5 5.6 4.9 4.4 3.9 3.6 3.3 drift reductionF 80 0.35 21.0 14.0 10.5 8.4 7.0 6.0 5.3 4.7 4.2 3.8 3.5 15 (35cm) Spacing 2 3.TS01-100 100# strainer for F 90 0.38 22.3 14.9 11.1 8.9 7.4 6.4 5.6 5.0 4.5 4.1 3.7 15-25 (35-60 cm) Highly engineered exit orifice for dropletsize 015-035VC 10* 0.15 8.9 5.9 4.5 3.6 3.0 2.5 2.2 2.0 1.8 1.6 1.5 uniformity, reduced drift and uniformTS01-50 50# strainer for C 15* 0.18 10.9 7.3 5.5 4.4 3.6 3.1 2.7 2.4 2.2 2.0 1.8 20 (50cm) Spacing 20-30 (50-75 cm) spray across the boomM 20 0.21 12.6 8.4 6.3 5.0 4.2 3.6 3.2 2.8 2.5 2.3 2.1 3 size 04-08M 30 0.26 15.4 10.3 7.7 6.2 5.1 4.4 3.9 3.4 3.1 2.8 2.6M 40 0.30 17.8 11.9 8.9 7.1 5.9 5.1 4.5 4.0 3.6 3.2 3.0 3D Nozzle Outperforms Flat Fan 03 M 50 0.34 19.9 13.3 10.0 8.0 6.6 5.7 5.0 4.4 4.0 3.6 3.3F 60 0.37 21.8 14.5 10.9 8.7 7.3 6.2 5.5 4.8 4.4 4.0 3.6 Features Part NumbersF 70 0.40 23.6 15.7 11.8 9.4 7.9 6.7 5.9 5.2 4.7 4.3 3.9 in pre-emerge weed control at multiple boom heightsF 80 0.42 25.2 16.8 12.6 10.1 8.4 7.2 6.3 5.6 5.0 4.6 4.2 Common Use Weed control,FastCapsF 90 0.45 26.7 17.8 13.4 10.7 8.9 7.6 6.7 5.9 5.3 4.9 4.5 plant health FC-3D100-015VC 10* 0.18 10.4 6.9 5.2 4.2 3.5 3.0 2.6 2.3 2.1 1.9 1.7 Alternating Tapered C 15* 0.21 12.7 8.5 6.4 5.1 4.2 3.6 3.2 2.8 2.5 2.3 2.1 Pattern Flat Fans FC-3D100-02GUIDANCE CONTROLS &SPRAYERC 20 0.25 14.7 9.8 7.4 5.9 4.9 4.2 3.7 3.3 2.9 2.7 2.5M 30 0.30 18.0 12.0 9.0 7.2 6.0 5.1 4.5 4.0 3.6 3.3 3.0 Advanced TaperedFC-3D100-025M 40 0.35 20.8 13.9 10.4 8.3 6.9 5.9 5.2 4.6 4.2 3.8 3.5 Technology Flat Fan35 M 50 0.39 23.2 15.5 11.6 9.3 7.7 6.6 5.8 5.2 4.6 4.2 3.9 FC-3D100-03M 60 0.43 25.5 17.0 12.7 10.2 8.5 7.3 6.4 5.7 5.1 4.6 4.2 Material Polyacetal FC-3D100-035M 70 0.46 27.5 18.3 13.8 11.0 9.2 7.9 6.9 6.1 5.5 5.0 4.6F 80 0.49 29.4 19.6 14.7 11.8 9.8 8.4 7.4 6.5 5.9 5.3 4.9 Spray Angle 100 FC-3D100-04F 90 0.53 - 20.8 15.6 12.5 10.4 8.9 7.8 6.9 6.2 5.7 5.2 10-90 PSI FC-3D100-05XC 10* 0.20 11.9 7.9 5.9 4.8 4.0 3.4 3.0 2.6 2.4 2.2 2.0 Pressure Range (0.7-6 BAR)VC 15* 0.24 14.5 9.7 7.3 5.8 4.8 4.2 3.6 3.2 2.9 2.6 2.4 FC-3D100-06C 20 0.28 16.8 11.2 8.4 6.7 5.6 4.8 4.2 3.7 3.4 3.1 2.8M 30 0.35 20.6 13.7 10.3 8.2 6.9 5.9 5.1 4.6 4.1 3.7 3.4 Configuration Tips, SnapLock FC-3D100-08M 40 0.40 23.8 15.8 11.9 9.5 7.9 6.8 5.9 5.3 4.8 4.3 4.0& SPRAY GUNS PRODUCTS INFORMATION 04 M 50 0.45 26.6 17.7 13.3 10.6 8.9 7.6 6.6 5.9 5.3 4.8 4.4 Optimum Boom Height Replacement Tip StrainerM 60 0.49 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 5.3 4.8 The 3D nozzle was proven superior in black grass M 70 0.53 - 21.0 15.7 12.6 10.5 9.0 7.9 7.0 6.3 5.7 5.2 control for pre-emerge herbicides compared to a 15 (35cm) Spacing 15-25 (35-60 cm) TS01-100 100# strainer for M 80 0.57 - 22.4 16.8 13.4 11.2 9.6 8.4 7.5 6.7 6.1 5.6 flat fan at multiple boom heights.(0.6l/ha Liberator F 90 0.60 - 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 6.5 5.9 size 015-035(diflufenican+ flufenacet) + 4l/ha Defy (Prosulfacarb) XC 10* 0.25 14.9 9.9 7.4 5.9 5.0 4.2 3.7 3.3 3.0 2.7 2.5 20 (50cm) Spacing 20-30 (50-75 cm) TS01-50 50# strainer for VC 15* 0.31 18.2 12.1 9.1 7.3 6.1 5.2 4.5 4.0 3.6 3.3 3.0 applied November 2015) size 04-08C 20 0.35 21.0 14.0 10.5 8.4 7.0 6.0 5.3 4.7 4.2 3.8 3.5C 30 0.43 25.7 17.1 12.9 10.3 8.6 7.3 6.4 5.7 5.1 4.7 4.33D Nozzle Delivers Improrms Flat Foved Ean fficiency05 M 40 0.50 29.7 19.8 14.9 11.9 9.9 8.5 7.4 6.6 5.9 5.4 5.0 3D Nozzle OutperfM 50 0.56 - 22.1 16.6 13.3 11.1 9.5 8.3 7.4 6.6 6.0 5.5 in pre-emerge weed control at multiple boom height lM 60 0.61 - 24.2 18.2 14.5 12.1 10.4 9.1 8.1 7.3 6.6 6.1 Reduce water volume without compromising weed controsM 70 0.66 - 26.2 19.6 15.7 13.1 11.2 9.8 8.7 7.9 7.1 6.5M 80 0.71 - 28.0 21.0 16.8 14.0 12.0 10.5 9.3 8.4 7.6 7.0M 90 0.75 - 29.7 22.3 17.8 14.9 12.7 11.1 9.9 8.9 8.1 7.4XC 10* 0.30 17.8 11.9 8.9 7.1 5.9 5.1 4.5 4.0 3.6 3.2 3.0VC 15* 0.37 21.8 14.5 10.9 8.7 7.3 6.2 5.5 4.8 4.4 4.0 3.6C 20 0.42 25.2 16.8 12.6 10.1 8.4 7.2 6.3 5.6 5.0 4.6 4.2C 30 0.52 - 20.6 15.4 12.3 10.3 8.8 7.7 6.9 6.2 5.6 5.1C 40 0.60 - 23.8 17.8 14.3 11.9 10.2 8.9 7.9 7.1 6.5 5.906 50 0.67 - 26.6 19.9 15.9 13.3 11.4 10.0 8.9 8.0 7.2 6.6MM 60 0.73 - 29.1 21.8 17.5 14.5 12.5 10.9 9.7 8.7 7.9 7.3M 70 0.79 - - 23.6 18.9 15.7 13.5 11.8 10.5 9.4 8.6 7.9M 80 0.85 - - 25.2 20.2 16.8 14.4 12.6 11.2 10.1 9.2 8.4M 90 0.90 - - 26.7 21.4 17.8 15.3 13.4 11.9 10.7 9.7 8.9XC 10* 0.40 23.8 15.8 11.9 9.5 7.9 6.8 5.9 5.3 4.8 4.3 4.0VC 15* 0.49 29.1 19.4 14.5 11.6 9.7 8.3 7.3 6.5 5.8 5.3 4.8VC 20 0.57 - 22.4 16.8 13.4 11.2 9.6 8.4 7.5 6.7 6.1 5.6C 30 0.69 - 27.4 20.6 16.5 13.7 11.8 10.3 9.1 8.2 7.5 6.9C 40 0.80 - - 23.8 19.0 15.8 13.6 11.9 10.6 9.5 8.6 7.9 At 10 GPA (100 L/Ha) the Hyproven supeori o3rD i n obzlzalcek o gurtapsesr forms 08 M 50 0.89 - - 26.6 21.3 17.7 15.2 13.3 11.8 10.6 9.7 8.9 The 3D nozzle was prFlat Fol an nozzles (FF) M 60 0.98 - - 29.1 23.3 19.4 16.6 14.5 12.9 11.6 10.6 9.7 contr for pre-emerge herbicides regardless ocfo wmpaater evdo ltuom aein pre-emergence blackgrass trials (source Syngenta UKM 70 1.06 - - - 25.1 21.0 18.0 15.7 14.0 12.6 11.4 10.5 flat fan at multiple boom heights.(0.6l/ha LiberatorM 80 1.13 - - - 26.9 22.4 19.2 16.8 14.9 13.4 12.2 11.2 (difluftrials, Liberenacator et) + 4l/ha Defy (PM 90 1.20 - - - 28.5 23.8 20.4 17.8 15.8 14.3 13.0 11.9 field enican+ fluf @ 0.4l/ha + Defy @r o4sulfl/haacarb) , applied Droplet size based on ASABE S572.1 standard. ap6th Nov 2015)plied November 2015)*For pressures lower than 15 PSI, nozzle spray angle may be reduced and will require a boom height of 30in to maintain spray distribution.3D Nozzle Delivers Improved EfficiencyReduce water volume without compromising weed control316At 10 GPA (100 L/Ha) the Hypro 3D nozzle outperforms Flat Fan nozzles (FF) regardless of water volume in pre-emergence blackgrass trials (source Syngenta UK field trials, Liberator @ 0.4l/ha + Defy @ 4l/ha, applied 6th Nov 2015)'