b'QUICK TEEJET CAPS & ADAPTER CAPS APPLICATORS & SPRAYERSDRY MATERIALHANDLINGCaps 1 2 3 4 5 6 7 8 9 10 11 12 13Black White Red Blue Green Yellow Brown Orange Gray Violet3 Lt. Blue4 Telemagenta5Lt. Green5 QUICKPART NUMBERTEEJETFOR USE WITH FLAT SPRAY TIPSQUICK TEEJETQUICK TEEJET CAPbarCAPS CAP ONLY & SEAT GASKET SET114441-*-CELR TeeJet Flat Spray Tips (Smaller Capacities)CP114440-*-CETRAILERS VALVES &FITTINGS114441-*-CELVICP25611-*-NY 25612-*-NYR TP StandardXRTurbo TwinJet AIXR TeeJet 0067 to 08 01 to 08 -015 to -06CP25611-9-PP1 25612-9-PP1 DG TeeJet TurboTeeJetOC TeeJet01 to 08TeeJet Flat Spray Tips (Larger Capacities)TANKS &ACCESSORIESCP25609-*-NY 25610-*-NYR TP StandardXR 10 to 20 10 to 15114443-*-CELRCP114442-*-CE114443-*-CELVITJ60 TwinJet AI Turbo TwinJetDG TwinJet AIXR TeeJet -02 to -06 -08 to -10PUMPS NOZZLES, TIPS & SPRAY GUNSCP25597-*-NY 25598-*-NYR AI TeeJet and Turbo TeeJet Induction SJ3 StreamJetAIUB TeeJet -015 to -06114502-*-CELR6CP114501-*-CE6 AI Turbo TwinJetTurbo TeeJet InductionTurbo TeeJet114502-*-CELVI6 -08 to -15 -08 to -10 -10 to -12CP98578-1-NY2 98579-1-NYR2AI3070TeeJet Flat Spray Tips (Smaller Capacities)CP25595-*-NY 25596-*-NYR Tips can be positioned in choice of two spray plane directionsparallel or perpendicular to wingsof Quick TeeJet cap.Locating STRAINERS & HOSENibCP25599-*-NY 25600-*-NYRTurbo FloodJetTK-VP FloodJet TK-VS FloodJet114445-*-CELRCP114444-*-CE COMBO-JET Spray Tips Engineered for New Dicamba Herbicide Formulations(contd)114445-*-CELVI The only spray tips recommended for Pulse Width Modulation SprayingPLANTEREQUIPMENTCP25607-*-NY 25608-*-NYR IMPORTANT DISCLAIMER FOR GENERAL & DICAMBA-TOLERANT CROP SPRAYING APPLICATIONS: TK FloodJet FL FullJet TX/TXA ConeJet TG Full Cone Hose Shank AITXA! Always verify the spray tips you intend to use are listed as approved nozzles on your chemicals label for dicamba-tolerant ConeJetCP25607-9-PP1 25608-9-PP1 herbicide applications. The below PWM tip charts are based on commonly used Pulse Width Modulation (PWM) spray systems, and the inherent pressure drops that occur through the solenoid associated with them. ENSURE your PWM system follows the same gauge and tip pressure relationships. ALWAYS confirm pressure at spray tip corresponds with label requirements PRIOR to spraying any chemical. Proper Seal 80% mark, as it allows significant increased speed (e.g. down a hill), as well as allows significant decreased speed without rate shortages/overages. CP18999-EPR coverage). As long as the duty cycle is maintained above 50% and under 100%, it should be suitable, but an ideal duty cycle might be around the 70- The duty cycle modulates the flow of a tip to keep a rate consistent across speed ranges, while applying the same pressure at the tip (for identical2. What is my ideal duty cycle when choosing a PWM spray tip? induction spray tip; however, with the closed chamber design, it allows for the PWM spray system to continue operating like normal.Yes. The way Wilgers drift reduction spray tips are designed allow them to maintain similar and greater levels of drift reduction compared to an air1. Can all Combo-Jet spray tips be used on PWM spray systems? For a few commonly asked questions, regarding the use of Combo-Jet spray tips with PWM systems: speed range.allowing users to see exceptional information relating to % drift, % of small droplets (coverage), as well as calculates your duty cycle at anytips with the systems. Wilgers TIP WIZARD spray tip calculator provides the most versatile calculator for pulse width modulation sprayers,With Pulse Width Modulation spray systems increasing in use, it is incredibly important to use correctly sized drift reduction spray ! COMMON QUESTIONS ABOUT USING PWM SPRAYERS & COMBO-JET SPRAY TIPSturn the lock-ring to seal the nozzle. Easy! Simply put the adapter on the square lugs, thenCombo-Jet to square lug cap adapter is easy. to use Combo-Jet spray tips. to adapt it to a square lug spray tip, using thelike TeeJet, Hypro, Arag), you will need an adapterIf you have a Combo-Jet nozzle body, and needIf you have a square lug nozzle body (brands Combo-Jet Nozzle Bodies(TeeJet, Hypro, Arag, etc.)Square Lug Cap Adapter for Cap Adapter for Square Lug Nozzle Bodies#40203-00#40204-00maintenance and observation of system performance to maintain accurate pressures is recommended. MPH MPH 14.519.414.5 14.5 3.6 7.3 19.4 9.7 76 10.9 4.8 0.98 60 MPH MPH 0.89 17.750 17.7 63 3.3 4.4 13.3 8.9 13.3 10.0 13.36.6 MPH MPH 40 15.80.80 11.9 7.9 15.8 5.9 11.9 11.98.9 4.0 3.0 51 MPH MPH 14.835 0.75 11.1 8.3 11.13.7 14.8 5.6 44 2.8 11.1 7.4 MPH MPH 10.3 7.7 3.4 6.9 10.313.7 10.3 5.1 2.6 38 13.70.69 30 - Patented - MPH MPH MR SINGLE PRE-ORIFICE DESIGN 9.4 9.4 6.3 4.7 12.5 7.0 32 3.1 2.3 25 0.63 9.412.5#40291-08 Specifications MR110-08 @ 20 US GPA 15 GPA PSI 20 GPA MR110-08 @ 15 US GPA MR110-08 -MPH MPH 10.914.510.9 69 7.3 3.6 2.7 8.2 10.9 5.5 14.5 60 0.73 MPH MPH 0.67 13.350 2.5 13.3 3.3 57 7.5 5.0 10.0 10.010.0 6.6 MPH MPH 11.940 0.60 8.9 8.92.2 5.9 11.9 8.9 46 6.7 4.5 3.0 MPH MPH 0.56 35 11.18.3 4.2 40 5.6 8.3 11.1 2.8 6.3 2.1 8.3MPH MPH 2.6 5.1 7.7 3.9 34 1.9 7.7 10.3 5.8 7.730 10.30.52 - Patented - MPH MPH MR SINGLE PRE-ORIFICE DESIGN 1.8 29 9.4 7.0 2.3 3.5 4.7 7.0 5.3 25 0.47 7.09.4- #40291-06 MR110-0620 GPA MR110-06 @ 15 US GPA PSI MR110-06 @ 20 US GPA Specifications 15 GPA Pres. (US GPM) (PSI) 50% 75% 50% 25% 75% 100% 100% 25% (US GPA) PICTURE & PART # Application RateSPEED (MPH) @ % DUTY CYCLE SPEED (MPH) @ % DUTY CYCLE GaugeRATE Pres.SPRAY TIP Sprayer Speed @15 US Gallon/Acre Application 20 US Gallon/Acre Application PWMFLOWTipStandard Spray System Specifications Pulse Width Modulation System Spray Specifications equirements. Always review and follow chemical label requirements for nozzle selection, min/max tip pressure, and all nozzle appliication r NOTE: Note, the MR series spray tips are certified for use with only a few of the Dicamba Herbicide chemical labels, as they provide finer coverage (compared to the UR & DR series) at the cost of more driftable fines. !MR Series Spray Tips: 2nd Stage Drift Reduction for Balanced Drift & Coverage COMBO-JET maintenance and observation of system performance to maintain accurate pressures is recommended. pressure relationships. ALWAYS confirm pressure at spray tip corresponds with label requirements PRIOR to spraying any chemical. Properinherent pressure drops that occur through the solenoid associated with them. ENSURE your PWM system follows the same gauge and tipherbicide applications. The below PWM tip charts are based on commonly used Pulse Width Modulation (PWM) spray systems, and theAlways verify the spray tips you intend to use are listed as approved nozzles on your chemicals label for dicamba-tolerant ! IMPORTANT DISCLAIMER FOR GENERAL & DICAMBA-TOLERANT CROP SPRAYING APPLICATIONS:The only spray tips recommended for Pulse Width Modulation Spraying (contd)Spray Tips Engineered for New Dicamba Herbicide FormulationsCOMBO-JETCP25607-*-NYCore Disc-CoreCOMBO-JET MR Series Spray Tips: 2nd Stage Drift Reduction for Balanced Drift & CoverageSPRAYERCONTROLS &GUIDANCEDisc Core (Insert Core into Seal) ! NOTE: Note, the MR series spray tips are certified for use with only a few of the Dicamba Herbicide chemical labels, as they provide finer coverage (compared to the UR & DR series) at the cost of more driftable fines.Always review and follow chemical label requirements for nozzle selection, min/max tip pressure, and all nozzle appliication requirements.Ceramic Disc-Core Standard Spray System Specifications Pulse Width Modulation System Spray SpecificationsCP26277-1-NY2 26278-1-NYR2 SPRAY TIP TipFLOWSprayer Speed @PWM15 US Gallon/Acre Application 20 US Gallon/Acre ApplicationD-Disc Core TXB ConeJet AITXB ConeJet Pres.RATE Application RateGaugeSPEED (MPH) @ % DUTY CYCLE SPEED (MPH) @ % DUTY CYCLEPICTURE & PART # (US GPA)(PSI) (US GPM) Pres. 25% 50% 75% 100% 25% 50% 75% 100%2 2 MR110-06- #40291-06 Specifications 15 GPA 20 GPA PSI MR110-06 @ 15 US GPA MR110-06 @ 20 US GPACP114395-1-NYB 114396-1-NYR 114396-1-NYR includes gasket and O-Ring (CP7717-M10.5x1.5-VI) MR SINGLE PRE-ORIFICE DESIGN 25 0.47 9.4MPH 7.0MPH 29 2.3 4.7 7.0 9.4 1.8 3.5 5.3 7.0TXR ConeJet- Patented - 30 0.52 10.3MPH 7.7MPH 34 2.6 5.1 7.7 10.3 1.9 3.9 5.8 7.7QJ4676-1/8-NYR Permits use of standard 1/89 and 1/49 nozzles. Can be used for mounting pressure gauge at the nozzle. 35 0.56 11.1MPH 8.3MPH 40 2.8 5.6 8.3 11.1 2.1 4.2 6.3 8.3QJ4676-45-1/4-NYR 45 Quick TeeJet cap with 1/49 NPT female threaded outlet 40 0.60 11.9MPH 8.9MPH 46 3.0 5.9 8.9 11.9 2.2 4.5 6.7 8.9QJ4676-90-1/4-NYR 90 Quick TeeJet cap with 1/49 NPT female threaded outlet 50 0.67 13.3MPH 10.0MPH 57 3.3 6.6 10.0 13.3 2.5 5.0 7.5 10.060 0.73 14.5MPH 10.9MPH 69 3.6 7.3 10.9 14.5 2.7 5.5 8.2 10.9MR110-08 -#40291-08 Specifications 15 GPA 20 GPA PSI MR110-08 @ 15 US GPA MR110-08 @ 20 US GPA90 included angle between outlets. When used with standard \x1fat fan tips produces a twin type spray patternQJ90-2-NYR MR SINGLE PRE-ORIFICE DESIGN MPH MPHfor improved coverage and canopy penetration. - Patented - 25 0.63 12.59.432 3.1 6.3 9.4 12.5 2.3 4.7 7.0 9.430 0.69 13.7MPH 10.3MPH 38 3.4 6.9 10.3 13.7 2.6 5.1 7.7 10.3NH3 PRODUCTS*Specify color code (see chart). 1 These caps only available in gray and rated to 150 psi (10 bar). 2 These caps only available in black. 3C olor available in CP25597, CP25611, CP114440, CP114442 and CP114444 caps. 4 Color available in CP114440, CP114442 and CP114501 caps.35 0.75 14.8MPH 11.1MPH 44 3.7 7.4 11.1 14.8 2.8 5.6 8.3 11.15 Color available in CP114501 cap. 6 This cap o\x1eered in Black, White, Light Green, Light Blue and Telemagenta only. 40 0.80 15.8MPH 11.9MPH 51 4.0 7.9 11.9 15.8 3.0 5.9 8.9 11.950 0.89 17.7MPH 13.3MPH 63 4.4 8.9 13.3 17.7 3.3 6.6 10.0 13.360 0.98 19.414.576 4.8 9.7 14.5 19.4 3.6 7.3 10.9 14.5ADAPTER CAPS AND SHUT OFF CAPS MPH MPH #40203-00 #40204-00 TECHNICAL INFORMATIONCap Adapter for Square Lug Nozzle Bodies Part # Description (TeeJet, Hypro, Arag, etc.)Square Lug Cap Adapter forCombo-Jet Nozzle Bodies 40204-00 SQ Lug (TeeJet) To Combo-Jet Adapter-Lock Ring (New)If you have a square lug nozzle body (brandsIf you have a Combo-Jet nozzle body, and need like TeeJet, Hypro, Arag), you will need an adapterto adapt it to a square lug spray tip, using the 40203-00 Combo-Jet To SQ Lug (TeeJet) Adapter to use Combo-Jet spray tips. Combo-Jet to square lug cap adapter is easy.QJ-W-PP Wilger Combo-Jet Body To TeeJet/Hypro Tip/Cap Simply put the adapter on the square lugs, then 55240-CELR Hardi To Quick Jet turn the lock-ring to seal the nozzle. Easy!40203-00 40204-00COMMON QUESTIONS ABOUT USING PWM SPRAYERS & COMBO-JET SPRAY TIPS 114447A-1-CELR TeeJet Blank Shutoff Cap w/ Gasket ! With Pulse Width Modulation spray systems increasing in use, it is incredibly important to use correctly sized drift reduction spray INDEXtips with the systems. Wilgers TIP WIZARD spray tip calculator provides the most versatile calculator for pulse width modulation sprayers, allowing users to see exceptional information relating to % drift, % of small droplets (coverage), as well as calculates your duty cycle at any 285 speed range. For a few commonly asked questions, regarding the use of Combo-Jet spray tips with PWM systems:1. Can all Combo-Jet spray tips be used on PWM spray systems?Yes. The way Wilgers drift reduction spray tips are designed allow them to maintain similar and greater levels of drift reduction compared to an air induction spray tip; however, with the closed chamber design, it allows for the PWM spray system to continue operating like normal. 2. What is my ideal duty cycle when choosing a PWM spray tip?The duty cycle modulates the flow of a tip to keep a rate consistent across speed ranges, while applying the same pressure at the tip (for identical coverage). As long as the duty cycle is maintained above 50% and under 100%, it should be suitable, but an ideal duty cycle might be around the 70-80% mark, as it allows significant increased speed (e.g. down a hill), as well as allows significant decreased speed without rate shortages/overages.'